Are you looking for an Astral pool heating cooling model AHP-500-R4 supplier in Dubai?
Operation and efficiency of the pool heat pump
The heat pump works through a simple and effective system to provide heat to the pool water.
This equipment has an evaporator responsible for collecting the calories from the outside air and transferring them to the pool water to increase its temperature. This implies that most energy used to heat the water comes from a natural medium, the air. In this way, only 20% of the power comes from an electricity source, while 80% results from the outside air.
It should also be noted that the heat pump is easy to install and can be installed in new construction pools or those already established. You only need an electrical and hydraulic connection, so with a simple and quick installation, you will benefit from a heat pump. Learn more about Astral Heat Pump AHP 030-R4.
All Astral AHP Heat Pump Models:-
- Astral Heat Cool Model AHP 030-R4
- Astral Heat Cool Model AHP 050-R4
- Astral Heat Cool Model AHP 060-R4
- Astral Heat Cool Model AHP 080-R4
- Astral Heat Cool Model AHP 100-R4
- Astral Heat Cool Model AHP 130-R4
- Astral Heat Cool Model AHP 200-R4
- Astral Heat Cool Model AHP 250-R4
- Astral Heat Cool Model AHP 400-R4
- Astral Heat Cool Model AHP 500-R4
Astral Swimming Pool Heating Cooling Model AHP 500-R4 Specification:-
TECHNICAL DATA SHEET FOR 50 HZ UNITS | ||
SWIMMING POOL HEAT PUMP SPECIFICATIONS- (50HZ) | ||
ASTRALPOOL HEATING COOLING MODEL:- | AHP 500-R4 | |
Cooling Capacity | kW | 150 |
Cooling Capacity | BTU/h | 510000 |
Cooling Power Input | kW | 52.1 |
Heating Capacity | kW | 210 |
Heating Capacity | BTU/h | 714000 |
Heating Power Input | kW | 44.8 |
Running Current (C/H) | Amp | 92.8/79.8 |
Power Supply | V/Hz | 415V/3N~/50Hz |
Compress Quantity | Nos. | 4 |
Compress Type | – | scroll |
Heat Exchanger | – | Twisted Double Coil Titanium Heat Exchanger |
Fan Quantity | Nos. | 2 |
Fan Power Input | W | 2000×2 |
Fan Speed | RPM | 920 |
Fan Direction | – | vertical |
CFM per Unit | – | 27988 |
Noise | db(A) | 67 |
Water Connection | mm | 110 |
Water Flow Volume | m3/hr | 50 |
Water Pressure Drop | kPA | 24 |
Ambient Temperature | °C | -15~53 |
COP | – | 4.69 |
EER | – | 2.88 |
Refrigerant | – | R407C |
Certification | – | Manufactured to CE Conformity |
Net Dimension | mm | 2175*1070*2070 |
Shipping Dimensions (l/w/h) | mm | 2240*1220*2120 |
Net weight/Shipping weight | kg | 960/1005 |
Max Power Input | kW | 62.5 |
Max Current Input | Amp | 114.4 |
How to choose the ideal heat pump for the pool
There are different elements to consider to choose the correct heat pump for your pool. Do not hesitate to contact us to receive personalized advice and correctly select the heat pump that suits your needs. Factors to consider are:
Technical characteristics of a heat pump
In addition to defining the needs and characteristics of our swimming pool to choose the ideal heat pump, it is also essential to understand the different factors that determine this equipment. Then, we will detail the various technical aspects of a pool heat pump to choose the equipment that best suits your pool.
heat pump power
Each heat pump’s power to increase the pool water is indicated in kW.
One of the ways to know the kW that we will need to heat the pool is to multiply the cubic meters (m3) that the collection has by 0.3.
Although this calculation is not very detailed and precise, it allows us to get an idea of ​​the necessary kW, considering that a thermal blanket is also used to retain heat better.
For example, we will measure a pool 6 meters long and 4 meters wide, with an average depth of 1.5 meters.
In any case, this data is for guidance since it is imperative to know the temperature, the area in which the pool is located, and the wind there. These elements account for 95% of the heat loss generated by the pump.
Coefficient of Performance or Coefficient of Performance
The COP (Coefficient of Performance in English) shows the ratio between the heat (or cold) supplied to the pool water and the energy consumed. Therefore, the higher the COP, the more energy efficient the heat pump will have.
In any case, it is essential to make sure that the measurements from which the heat pumps are compared have been taken under the same conditions: air and water temperature.
Minimum operating temperature
When choosing the heat pump, the minimum temperature at which the device can work must also be considered.
This, depending on the climatic characteristics of the area in which your pool is located, will allow you to know the temperature at which it can start to defrost and function correctly.
heat pump sound
This equipment to heat the pool water can generate some noise when it works, so it is essential to consider the sound of these. When choosing the ideal heat pump for your pool, the decibels (dB) emitted by the equipment must be considered.
Manufacturers usually indicate dB in two different measurements: one next to the equipment and the other about 10 meters away.
Astral Heat Pump AHP 500-R4 Spare Parts:-
- AHP 500R4 Display Controller
- AHP 500R4 Water Flow Switch
- AHP 500R4 Temperature Sensor
- AHP 500R4 Pressure Sensor HP
- AHP 500R4 Pressure Sensor LP
- AHP 500R4 4 Way Valve
- AHP 500R4 Heat Exchange SS
- AHP 500R4 Compressor
- AHP 500R4 Fan Motor
- AHP 500R4 Blade
- AHP 500R4 Main Controller
- AHP 500R4 Fan Capacitor
- AHP 500R4 Compressor Capacitor
- AHP 500R4 Dry Filter
- AHP 500R4 3 Phase Monitor
- AHP 500R4 AC Relay